Work through the same five-step method used in Philippine PV installer training โ load analysis, panel sizing, inverter sizing, battery bank, and charge controller โ for off-grid, on-grid, or hybrid systems.
System Settings
Philippines average is ~4โ4.5 PSH (lower in rainy season / Luzon north, higher in Mindanao). Adjust to your site's solar resource data.
Higher bus voltage = lower current = smaller conductors, per PEC ampacity rules.
Covers wiring, temperature, dust, and inverter conversion losses โ consistent with PEC's continuous-duty margin (conductors/OCPD sized โฅ125% of load).
Roof / Site Dimensions
Checks whether the physical roof can actually fit the number of panels each mode recommends โ not just the electrical sizing.
Clear pathway kept along ridges, hips, and eaves for fire access and maintenance โ ~0.9m (3 ft) is a common minimum per fire code and TESDA rooftop-mounting practice.
of โ mยฒ total roof area
System Wiring Diagram โ Single Line
PV โ grid-tie inverter โ main distribution panel, with a bi-directional meter for energy export credit.
Breaker and SPD ratings shown are sized at 125% of calculated current, per PEC continuous-duty practice โ verify against manufacturer datasheets before installation.
01Load Analysis
Average Monthly Consumption (kWh)Pull this from the customer's electric bill (Meralco / co-op statement, average of last 3โ6 months).
03Grid-Tie Inverter Sizing
On-grid inverter is sized to the total array output, not appliance surge โ the utility grid absorbs starting currents.
Selected Inverter Rated Power (kW)Enter the actual inverter model's rated AC power for the EVALUATE check below.
02PV Panel Sizing
Panel Rating (W)Photorealistic PV Layout (Dual MPPT Wiring)
Visual representation showing exactly how the calculated panels are divided across two internal MPPT trackers.
PROBill of Materials (BOM) Export
Enter a valid 9-digit pro code generated by the Solar-Sizing-Code-Generator.html to unlock the detailed BOM export capability. Codes expire after 1 hour.
This calculator reproduces the standard load-analysis โ panel โ inverter โ battery โ charge-controller sizing sequence taught in TESDA's Photovoltaic Systems Design and Installation curriculum, for preliminary estimation and training purposes only. It is not a substitute for a licensed engineer's system design, permit drawings, or manufacturer datasheet verification.